Statim Dental Steam Sterilizer N Type Autoclave with Vacuum and Steam Sterilization Equipment

Class N autoclaves are used for sterilizing solid and porous loads like instruments, fabrics, and glassware. Ensure items are clean and dry before loading. Place them in autoclave pouches or wraps for proper sterilization. Add distilled water for steam generation. Set sterilization parameters according to load type and size. Close door securely, initiating the cycle. Once completed, allow pressure to normalize before opening. Check sterilization indicators for validation. Class N autoclaves use gravity displacement for air removal, suitable for most non-hollow items. Follow manufacturer guidelines for optimal performance and safety.

Product Description

Here’s a brief overview of how to use a Class N autoclave:

Class N autoclaves are commonly used in medical and dental settings for sterilizing solid instruments, porous loads, and wrapped or unwrapped items that are not sensitive to heat and moisture. They operate using a gravity displacement method, where air is removed from the sterilization chamber through steam penetration.

1. Preparation:

Before starting the sterilization cycle, ensure that the autoclave chamber is clean and free from any debris or residue. Arrange the items to be sterilized in accordance with the manufacturer’s instructions, ensuring proper spacing and orientation to allow steam penetration.

2. Loading:

Load the items into the sterilization chamber, taking care not to overcrowd or block the steam circulation. Place wrapped items on trays or racks, ensuring adequate separation to facilitate steam penetration and promote even sterilization.

3. Water Filling:

Fill the autoclave’s water reservoir with distilled or demineralized water, following the manufacturer’s guidelines regarding the recommended water level. Proper water filling ensures the generation of steam necessary for sterilization.

4. Cycle Selection:

Select the appropriate sterilization cycle based on the type of items being sterilized and the manufacturer’s recommendations. Class N autoclaves typically offer preset cycles for different load types, including standard unwrapped, wrapped, and liquid cycles.

5. Start Cycle:

Close the autoclave door securely and initiate the sterilization cycle according to the selected parameters. The autoclave will begin heating the water to generate steam, and once the desired temperature and pressure are reached, the sterilization phase will commence.

6. Sterilization Phase:

During the sterilization phase, steam is circulated throughout the chamber, effectively killing microorganisms present on the surfaces of the items being sterilized. The duration of the sterilization phase varies depending on the cycle selected and the load type, typically ranging from 10 to 30 minutes.

7. Drying Phase:

After the sterilization phase is complete, the autoclave may initiate a drying phase to remove excess moisture from the sterilized items. This helps prevent condensation and ensures that the items are thoroughly dried before removal from the chamber.

8. Cooling and Unloading:

Once the sterilization and drying phases are complete, the autoclave will gradually cool down, allowing the chamber pressure to return to normal levels. Once it’s safe to do so, open the autoclave door carefully and remove the sterilized items using sterile gloves or instruments.

9. Documentation:

Record the sterilization cycle parameters, including the cycle type, duration, temperature, and pressure, in the autoclave log or sterilization record. Proper documentation is essential for quality control and regulatory compliance.

By following these steps and adhering to the manufacturer’s instructions, users can effectively and safely sterilize medical and dental instruments using a Class N autoclave. Regular maintenance and validation of the autoclave’s performance are also crucial to ensure consistent and reliable sterilization results.