Class N autoclaves work on the principle of high-pressure steam sterilization. Items to be sterilized are placed inside the autoclave chamber, and the air inside is removed through a vacuum process or displacement by steam. Once the chamber reaches the desired temperature and pressure, typically around 121°C and 134°C, steam is introduced, penetrating and sterilizing the items. The high pressure ensures efficient sterilization by denaturing proteins and destroying microorganisms, including bacteria, viruses, and spores. After the sterilization cycle, items cool down before they can be safely removed.
Class N autoclaves are widely used in medical and dental settings for sterilizing instruments, equipment, and other items that can withstand high heat and pressure. Here’s a step-by-step guide on how to use a Class N autoclave effectively:
Ensure the autoclave is placed on a stable surface with adequate ventilation. Check that the water reservoir is filled to the appropriate level as per manufacturer instructions. Inspect the sealing ring and ensure it’s in good condition to prevent steam leaks.
Arrange the items to be sterilized inside the autoclave chamber, ensuring proper spacing and orientation to allow steam to reach all surfaces. Avoid overloading the chamber, as this can hinder steam penetration and affect sterilization effectiveness.
Select the appropriate sterilization cycle based on the type of items being sterilized, load size, and desired sterilization parameters. Class N autoclaves typically offer a variety of preset cycles for different applications, including standard, wrapped, unwrapped, and porous loads.
Close the autoclave door securely and ensure it’s properly sealed. Start the selected sterilization cycle using the control panel or touchscreen interface. The autoclave will automatically begin the heating and pressurization process.
During this phase, the autoclave heats the water to produce steam, which raises the temperature and pressure inside the chamber. The sterilization cycle typically consists of three stages: heating, sterilization, and drying. Monitor the cycle progress on the display panel and ensure that the chamber reaches and maintains the specified temperature and pressure for the recommended duration.
Once the sterilization phase is complete, the autoclave will gradually depressurize and cool down. Some models may have a built-in drying phase to remove excess moisture from the items. Wait for the chamber to reach a safe temperature before opening the door.
Carefully remove the sterilized items from the autoclave chamber using heat-resistant gloves or tools. Inspect the items for any signs of damage or moisture. Store the sterilized items in a clean, dry environment until ready for use.
After each use, clean the autoclave chamber and accessories according to manufacturer guidelines to prevent buildup of residue and maintain optimal performance. Regularly inspect and replace worn-out components such as sealing rings and filters to ensure safety and reliability.
Following these steps will help ensure safe and effective sterilization using a Class N autoclave, helping to protect patients and staff from the risk of infection.