The Class N type steriliser is a type of steam sterilization equipment used in healthcare, laboratory, and industrial settings to effectively kill a wide range of microorganisms, including bacteria, viruses, fungi, and spores. It utilizes high-pressure saturated steam as the primary sterilizing agent, with a sterilization cycle typically taking 30-60 minutes. Designed to meet strict regulatory standards, Class N autoclaves are commonly used to sterilize a variety of heat-resistant items, such as surgical instruments, laboratory glassware, and other medical and industrial equipment. It plays an important role in clinic.
Model | EN18/ EN23 |
Capacity | 18L/23L |
Class | N |
Display | LED Digital |
Rated Working Pressure | 0.22Mpa |
Rated voltage | AC220V+22V, 50+1Hz |
Input power | ≤ 1800VA |
Rated Working Temperature | 121°C/134°C |
Water tank | About 1 liter |
The normal use of the environment Humidity |
≤85% |
Air pressure | 70kPa – 106kPa |
Temperature | 5 ~ 40℃ |
Noise | <70db |
The following are features of this n type steriliser
SAFETY DEVICES:
1.Main fuses
Automatically disconnect the circuit When high current or over temperature causes of short circuit.
2.Safety valve
Automatically pressure released When the pressure inside is too high.
3.Door lock device
Sterilizer can start work with door closed well.
4.Fault indication system
When the numerical value of the sterilization cycle exceeds the specified range, or the cause of the media supply fails to fully meet the specified variation, the failure indication is provided and the acoustic signal is indicated
Advanced Process Control:
Class N sterilizers incorporate advanced process control algorithms and sensors to precisely monitor and regulate the critical parameters of the sterilization cycle, such as temperature, pressure, and exposure time.
This ensures consistent and reliable sterilization results, even with varying load sizes and compositions.
User-Friendly Interface:
Modern Class N sterilizers feature intuitive, user-friendly interfaces, such as touchscreen displays, that simplify the operation and programming of the equipment.
This can include features like pre-programmed cycle options, on-screen instructions, and customizable settings.
Modular Design:
Some Class N sterilizers are designed with a modular construction, allowing for easy replacement of individual components or upgrades to specific functionalities.
This can improve the flexibility and longevity of the equipment, as well as facilitate maintenance and service activities.